Site survey, purpose and coverage design
Required scenes, entries, exits, assets, public areas, blind spots, camera purpose, site constraints and expansion priorities.
CCTV & VIDEO SURVEILLANCE
MiCiS designs, installs and supports commercial CCTV across your sites. We plan network connectivity and supported access-control integrations alongside camera coverage. One team coordinates site survey, cameras and lenses, cabling, network and PoE, recording and storage, remote access, maintenance and integrations so coverage, retention and responsibilities remain clear.
Entries, exits, assets, public areas, blind spots and required views
Camera type, field of view, day/night performance and environment
Mounting, structured cabling, switching, VLANs, bandwidth and UPS
NVR/VMS, recording mode, retention target, time sync and export
Users, remote access, health checks, exports, firmware and lifecycle
WHAT WE MANAGE
A CCTV system is more than a camera count. The purpose of each view, lighting and scene conditions, lens selection, mounting, cabling, PoE, network capacity, recording mode, storage, time synchronisation, user access, export and maintenance all affect whether the system produces useful footage. MiCiS brings those layers into one documented service path.
Required scenes, entries, exits, assets, public areas, blind spots, camera purpose, site constraints and expansion priorities.
Camera form factor, field of view, focal length, day/night behaviour, exposure, weather, impact and mounting conditions.
Mounting locations, pathways, structured cabling, switching, PoE budgets, VLANs, bandwidth, uplinks and UPS dependencies.
NVR or VMS configuration, recording schedules, event recording, storage model, retention target, time sync and export.
User roles, supported clients, secure remote access, mobile viewing, evidence export, audit context and authorised handover.
Agreed camera and recorder checks, storage condition, firmware, cleaning, focus, time, access, fault follow-up and lifecycle planning.
VIDEO EVIDENCE BUILT IN
A live picture is not the same as a dependable video record. Field of view, lighting, image settings, time synchronisation, network and power, recording health, storage, retention, user access and export all affect whether footage can be found and understood when it is needed. MiCiS designs and tests those controls as one evidence path.
HOW THE SERVICE IS DELIVERED
CCTV delivery crosses site access, mounting, cabling, power, PoE, network capacity, camera placement, recording and storage design, user access and operational policy. MiCiS defines the required views, coordinates the delivery dependencies, installs and commissions the system, validates representative recording and export, and retains the records needed for maintenance and controlled change.
Review site risks, required scenes, existing equipment, lighting, access, mounting, pathways, power, network, users, retention and integration requirements.
Select cameras and lenses, confirm views and mounting, size network, PoE, recorder and storage, define recording, access and cutover, and coordinate site dependencies.
Install agreed equipment, configure cameras, network and recording, tune representative scenes, test playback, time, retention assumptions, remote access and export.
Retain camera and system records, perform agreed checks and maintenance, coordinate faults, review storage and access, and plan expansion and lifecycle actions.
END-TO-END VIDEO EVIDENCE PATH
A usable video record depends on the scene and lighting, camera and lens, mounting and cabling, PoE and power, switching and bandwidth, time synchronisation, recording software, storage, retention, user access and export. MiCiS maps that chain so faults and changes can be tested beyond a green camera-status icon.
MiCiS can trace or coordinate a fault or change across scene, camera, cabling, power, network, recording, storage and client-access layers while retaining one documented escalation context. Product vendors, platform providers, property stakeholders and other third parties retain their own responsibilities.
FREQUENTLY ASKED QUESTIONS
A CCTV proposal should make camera purpose, site coverage, lighting, recording and retention, network and power dependencies, remote access, maintenance, integrations and operating responsibilities clear before work begins. These questions most often affect design, cost, usefulness and ongoing support.
The process begins with the purpose of each view: general overview, entry or exit activity, asset protection, movement through a space or another defined operational need. MiCiS then considers distance, angle, mounting height, lighting, motion, obstructions, day and night conditions, environmental exposure, network and power pathways and the level of visible detail required. The resulting plan is site-specific rather than based only on a camera count.
Storage depends on camera count, resolution, frame rate, compression, recording schedule, motion or event activity, scene complexity, retention target and any redundancy requirement. The design should state the assumptions used rather than presenting retention as an unconditional guarantee. MiCiS sizes and documents the proposed storage model and validates the configured recording and playback path during commissioning.
Sometimes. Reuse depends on physical condition, image quality, credentials, supported protocols, firmware, power requirements, cabling performance, PoE capacity, network design, recorder or VMS compatibility, channel and feature licences, storage condition and vendor support. MiCiS can assess the existing environment and identify what can remain, what introduces risk and what should be replaced or separated from the new design.
The required image depends on what the organisation needs to see and the conditions in which it must be seen. Distance, field of view, lens, resolution, lighting, motion, shutter, exposure, compression and viewing angle all affect visible detail. A high-resolution camera alone does not guarantee a useful result. MiCiS defines the purpose of the view and tests representative scenes against the agreed expectation.
Access should be limited to authorised users and supported devices, with named accounts, appropriate roles, strong authentication where the platform supports it, controlled administrator access and a documented offboarding process. Remote access may use a vendor service, secure application, VPN or another agreed path. The design should also identify who owns account recovery, mobile devices, exports and access review.
Different failures require different controls. Design options may include UPS-backed switching and recording, redundant storage or recording components, local camera storage, network-path resilience, health checks, alerts and documented restoration procedures. These controls must be explicitly scoped and tested; a camera appearing online does not prove that video is being retained correctly or that every failure mode is covered.
Availability depends on the selected cameras, recorder or VMS, feature licences, processing location, scene conditions and the connected systems. Before audio, biometric or facial functions, number-plate recognition or automated alerts are enabled, the organisation should define the operational purpose and obtain appropriate privacy, workplace, legal and policy advice. MiCiS can configure the agreed technical scope but does not determine the organisation’s lawful basis or operating policy.
Live monitoring, after-hours response, alarm verification and incident response are not assumed unless they are specifically contracted and documented. Where the relevant components are within the MiCiS scope, MiCiS can retain one technical context and trace or coordinate faults across camera, cabling, power, network, recorder, storage, remote client and integration layers. Other providers may retain their own monitoring, property, platform or response responsibilities.
Start with a practical review of your sites, required views, lighting, existing cameras and cabling, network and power, recording platform, retention, remote access, maintenance and integration requirements. MiCiS will identify coverage gaps, infrastructure and lifecycle dependencies, and the right next step for a documented commercial video system.